MSA Planner Dashboard

Auto-select gauges for MSA study by location, criticality, gauge family, range, usage, calibration, and prior evidence.

Selected for Planning
0
Gauges selected by planner rules
High Priority
0
Critical / audit-facing risk
Blocked
0
Calibration, master, part, or operator dependency
Weekly Capacity
18
Studies per week across QA team
Planned Completion
4w
Based on current queue and capacity

MSA Planning Queue

All selected studies · highest risk first
PriorityGaugeFamilyRangeLocationRequired StudyPlanner Priority Score
click for breakdown
Action

Planner Selection Breakdown

Select a reason to see linked studies
This pane is linked to the current study queue. Each count below is calculated from the same planner rows shown in the MSA Planning Queue. Priority now considers CTQ parameters, process capability gaps, conditional GRR >10%, MIW Quality / PED / Operations feedback, and instrument tolerance/sensitivity.

By Gauge Family

Queue split
FamilyCountAvg Score

By Location

Plant / area risk
LocationCountStatus

By Study Type

Workload mix
Study TypeCountCapacity Fit

Base MSA Study Creation

Create draft from MSA matrix
Step 1Select ItemGauge, instrument or equipment type is pulled from the MSA applicability matrix.
Step 2Apply MatrixMSA matrix recommends the applicable study type based on gauge, instrument or equipment type.
Step 3Sample PlanParts, trials, appraisers, reference values and acceptance criteria.
Step 4Dependency CheckCalibration, master, samples, operators and Cpk context.
Step 5Submit DraftDraft moves to reviewer queue before execution.

1. Gauge / Instrument / Equipment Selection

Select the item category and type. The applicable MSA studies are pulled from the uploaded MSA applicability matrix.
Recommendation is now embedded here: the applicable study type, sample plan and acceptance criteria are generated directly from the configured MSA applicability matrix. Separate Study Recommendation view has been removed to avoid duplicate navigation.

2. Location / Organisation Scope

This scope controls whether an existing MSA is reusable or whether a new study is needed.

3. Process / Characteristic Scope

Selecting the process automatically populates characteristic, criticality, tolerance, sample plan and recommended study type.
Process-driven defaults will appear here.

4. MSA Study Definition

5. Matrix Recommendation Summary

6. Dependency / Readiness Check

Created Study Drafts

Draft / submitted / approved / modification required
Study IDGaugeStudy TypeFeatureStatusReviewerVersionLast ActionAction

MSA Approval / Modification Workflow

Controlled study lifecycle

1. Draft Created

Planner-generated draft study is created with gauge context, range group, feature and recommended method.

Editable

2. Submitted for Review

Quality reviewer checks method, sample plan, reference master and Cpk context.

Review

3. Modification Required

Reviewer may request change in appraisers, parts, study type, acceptance rule or scope.

Rework

4. Approved / Released

Approved study is version locked and can be executed or counted as planned evidence.

Locked

Reviewer Queue

Studies awaiting decision
Study IDGaugeStudy TypeStatusPlanner Priority ScoreReviewer Action

Approval Decision Panel

Select a study

Cp / Cpk Context for MSA Planning

Process capability is context, not a replacement for MSA
Capability ConditionMSA Planning ImpactPriority Effect
Cpk ≥ 1.67Stable process; normal MSA cycleNormal
1.33 ≤ Cpk < 1.67Maintain coverage; due-soon studies planned normallyControlled
1.00 ≤ Cpk < 1.33Prioritize missing/overdue MSA for critical gaugesIncrease
Cpk < 1.00Escalate: measurement uncertainty may mask process nonconformanceHigh

Capability-Linked Gauge Queue

Critical process first
GaugeFeatureCpkMSA StatusPlanner Impact

Planner Action

Detailed action workflow for the selected gauge.

Gauge Family / range Score Study type

Action Context

Selected gauge

Recommended Workflow

Next steps

Required Inputs / Evidence

Before closure
EvidenceStatusOwner

Linked Score Rationale

Why this action is prioritized

MSA Planner → Workflow Step

Workflow Step Detail

Editable workflow step form for the selected action.

Gauge Family / range Draft Owner

Editable Step Form

Enter data required to complete this step
Step Action type Requires Review Can Submit

Completion Checklist

Mark before submit

Output / Evidence & Acknowledgement Inputs

System evidence, owner acknowledgement and attachments

Linked Context

Gauge, score and study linkage

Planner Priority Score Drill-down

MSA Planner → Score Drill-down

Priority
Planner Priority Score
0
Risk-based planning urgency
Study Type
-
Recommended MSA study
Gauge Context
-
Family and range
Location
-
Plant / area / line

Study / Gauge Summary

Status

Recommended Workflow

Planner action path

    Dependency Blockers

    Fix these before MSA can start
    Gauge IDFamilyLocationBlockerImpactOwnerAction

    Planner Rules

    Selection, scoring and workflow rules
    These rules explain how the planner selects gauges, instruments and equipment for MSA study. The rules are aligned with the applicability matrix, CTQ priority, process capability, previous MSA/GRR evidence, tolerance/sensitivity, feedback and dependencies.

    1. Selection Trigger Rules

    Why an item enters planning
    TriggerRulePlanner Action
    MSA DueRequired study is not created, linked, approved or valid for the current usage context.Plan Study
    Failed MSAPrevious MSA failed acceptance criteria or GRR >30%.CAPA / Re-study
    Conditional GRRPrevious GRR is >10% and ≤30%; accepted only with condition or improvement plan.Review / Re-study
    Overdue / Due SoonMSA validity has expired or renewal window is approaching.Renewal Plan
    BlockedCalibration, master, samples, CAPA or operator dependency prevents execution.Fix Dependency
    Usage Context ChangeOperator group, range, part feature, process/location, repair status or usage intensity has changed from the approved MSA scope.Revalidate Scope

    2. MSA Applicability Rule

    Gauge / instrument / equipment matrix
    Item CategoryMatrix SourceHow recommendation is created
    GaugeGauge applicability matrixBias, Linearity, Stability, R&R Variable and/or Attribute study are selected from configured gauge type.
    InstrumentInstrument applicability matrixStability, R&R Variable and Repeatability are selected based on instrument type and usage location.
    EquipmentEquipment applicability matrixLinearity, Stability, R&R Variable and Repeatability are selected based on equipment type.

    3. Planner Priority Score Master

    100-point scoring model
    FactorScoring RuleMax
    CTQ / product parameter priorityCritical-to-quality / customer-critical = 20; Major = 14; Minor = 8.20
    Process capability gapCpk <1.00 = 15; 1.00–1.32 = 10; 1.33–1.66 = 4; ≥1.67 = 0.15
    Current MSA evidence + Historical GRRFailed MSA or GRR >30% = 20; MSA Due = 16; conditional GRR >10% = 14; Overdue/Blocked = 12; Due Soon = 6; accepted/currently valid = 0.20
    MIW Quality / PED / Operations feedbackFeedback from 3 functions = 10; 2 functions = 8; 1 function = 5; none = 0.10
    Tolerance and sensitivity riskTolerance risk up to 8 points; instrument sensitivity up to 7 points.15
    Usage / context changeOperator/range/part/location/repair/high-usage change = 10; no major change = 4.10
    Dependency readinessNo blocker = 10; one dependency = 6; two dependencies = 3; three or more = 0.10

    4. Workflow Routing Rules

    Action selection
    ConditionWorkflow
    MSA Due / Due Soon / OverduePlan Study
    Failed MSA or GRR >30%CAPA / Re-study
    Conditional GRR >10%Review / Re-study
    Calibration/master/sample/operator/CAPA blockerFix Dependency

    5. Governance Rules

    Audit readiness
    Governance ControlRule
    Reviewer approvalDraft studies must be approved before execution.
    Version lockApproved study scope, sample plan and acceptance criteria are locked.
    Evidence traceabilitySelection reason, score breakdown, matrix source and dependencies are retained.
    Modification controlChanges after approval require modification request and re-approval.

    MSA Applicability Configuration

    Gauge / Instrument / Equipment matrix
    Configure which MSA studies are applicable for each item type. These rules feed the Study Creation view and control the recommended MSA study, sample plan and acceptance criteria.

    Configured Item Types

    0 rules

    Edit Applicability Rule

    Select a row or add new

    Applicable MSA Studies

    Select or edit a rule to preview the study recommendation.

    Selection Evidence Preview

    Audit-ready justification
    Each planned gauge carries the reason why it was selected, the rule that selected it, the required study type, the blocking dependencies, and the risk score. This makes the planner defensible during customer or IATF audits.
    Evidence ItemStatus
    Gauge master and active production usageLinked
    Location / line / process mappingLinked
    Critical characteristic mappingLinked
    Gauge family + range policyLinked
    Calibration dependency3 blockers
    MSA approval evidenceGaps found

    Export Pack

    Planner output
    Export includes: selected gauge queue, priority score trace, required study type, dependency blockers, owners, planned week, and audit justification.